        高壓介電強度擊穿試驗儀

        型 號BDJC-50KV

        更新時間2024-11-23

        廠商性質生產(chǎn)廠家

        報價

        產(chǎn)品描述:高壓介電強度擊穿試驗儀

        產(chǎn)品概述

        高壓介電強度擊穿試驗儀試驗方式:直流/交流:擊穿試驗、耐壓試驗、階梯試驗
        顯示方式:曲線/數(shù)據(jù)顯示,數(shù)據(jù)打印。
        試驗空間:絕緣油/空氣
        升壓速率:0.1KV/S-3KV/S
        整機精度:≤2%

         

         

        高壓介電強度擊穿試驗儀性能特點:
        1、主要由升壓系統(tǒng)、測量系統(tǒng)、A/D轉換器、放電系統(tǒng)、電極、油箱、電極定位架、計算機數(shù)據(jù)處理系統(tǒng)、軟件等組成;
        2、計算機---A/D轉換器---測量控制系統(tǒng)---調壓裝置---升壓變壓器---試樣;
        3、高壓變壓器主要產(chǎn)生試樣所需的直流電壓;
        4、調壓器用于調節(jié)升壓變壓器輸入端電壓以產(chǎn)生高壓所需的輸入電壓;
        5、電壓測量主要是從高壓變壓器測量端測量,高壓變壓器測量端和高壓端是線性的;
        6、放電系統(tǒng)在試驗做完以后放電,以免產(chǎn)生放電對人身的危害;(當試驗結束后,機器部件仍可能存在殘留的高電壓,此殘留電壓足以對人產(chǎn)生致命的傷害,配備此棒,完好的解決此安全隱患)。

         

         

        組成:
        1、升壓部件:由調壓器和高壓變壓器組成0~50KV的升壓部分。
        2、動部件:由步進電機均勻調節(jié)調壓器使加給高壓變壓器的電壓變化。
        3、檢測部件:由集成電路組成的測量電路。通過信號線把檢測的模擬信號和開關信號傳給計算機。
        4、計算機軟件:通過智能電路把由檢測設備采集的測控信號傳給計算機。計算機根據(jù)采集的信息控制設備運行并處理試驗結果。
        5、試驗電極:根據(jù)國家標準(1408.1-2006)隨設備提供三個電極,具體規(guī)格為:Ф25mm×25mm兩個;Ф75mm×25mm一個。(訂做除外)

         

         

        性能特點:
        1、主要由升壓系統(tǒng)、測量系統(tǒng)、A/D轉換器、放電系統(tǒng)、電極、油箱、電極定位架、計算機數(shù)據(jù)處理系統(tǒng)、軟件等組成;
        2、計算機---A/D轉換器---測量控制系統(tǒng)---調壓裝置---升壓變壓器---試樣;
        3、高壓變壓器主要產(chǎn)生試樣所需的直流電壓;
        4、調壓器用于調節(jié)升壓變壓器輸入端電壓以產(chǎn)生高壓所需的輸入電壓;
        5、電壓測量主要是從高壓變壓器測量端測量,高壓變壓器測量端和高壓端是線性的;
        6、放電系統(tǒng)在試驗做完以后放電,以免產(chǎn)生放電對人身的危害;(當試驗結束后,機器部件仍可能存在殘留的高電壓,此殘留電壓足以對人產(chǎn)生致命的傷害,配備此棒,完好的解決此安全隱患)。

         

         

         

        整機組成:
        1、升壓部件:由調壓器和高壓變壓器組成0~50KV的升壓部分。
        2、動部件:由步進電機均勻調節(jié)調壓器使加給高壓變壓器的電壓變化。
        3、檢測部件:由集成電路組成的測量電路。通過信號線把檢測的模擬信號和開關信號傳給計算機。
        4、計算機軟件:通過智能電路把由檢測設備采集的測控信號傳給計算機。計算機根據(jù)采集的信息控制設備運行并處理試驗結果。
        5、試驗電極:根據(jù)國家標準(1408.1-2006)隨設備提供三個電極,具體規(guī)格為:Ф25mm×25mm兩個;Ф75mm×25mm一個。

         

         

         

        參數(shù)
        輸入電壓: 交流 220 V  

        輸出電壓: 交流 0--100 KV ;/直流 0—100 KV


        電器容量: 10KVA   

        高壓分級: 0-100KV  

        升壓速率:0.01-5.0kv(備注:滿足標準要求并可以根據(jù)用戶需求設定不同的升壓速率)


        06、試驗方式: 交流試驗/直流試驗:1、勻速升壓   2、梯度升壓 3、耐壓試驗


        試驗介質:空氣,試驗油   安裝靈敏度較高的過電流保護裝置保證試樣擊穿時在0.05S內(nèi)切斷電源。  儀器配備先進的故障報警系統(tǒng) 避免用戶操作故障儀器發(fā)生危險。(上位機報警和下位機報警)

         

         

         

        軟件功能:
        01、軟件平臺:WINDOWS窗口操作平臺,界面直觀,便于操作
        02、曲線顯示:在實驗過程中可以動態(tài)顯示試驗曲線
        03、數(shù)據(jù)導出:可以對試驗結果導入EXCEL表格
        04、實驗報告:可以人為設置報告名稱,并對實驗報告進行打印
        05、試驗方式:可以根據(jù)需求對直流試驗和交流試驗進行靈活選擇
        06、試驗方法:可以根據(jù)需求自行選擇擊穿電壓、耐壓試驗、梯度試驗
        07、參數(shù)設置:可以根據(jù)不同的試驗方式及試驗方法靈活設置所需的不同參數(shù)值
        08、試樣設置:可對不同標準的試樣參數(shù)靈活設置
        09、人員管理:設置用戶名及密碼,不同的操作員登入進行不同的試驗,互不影響
        10、標準選擇:含有不同標準,可根據(jù)需求自行選擇
        11、連續(xù)操作:連續(xù)操作試驗時,可直接在軟件里選擇電機復位,進行二次試驗

         

         

        將介電試驗機的一根試驗引接到作為一個電極的試樣的導體上,并另一根試驗引接到作為另一個電極的金屬試棒上,電壓應從零開始上升至28.1規(guī)定的試驗電壓。升壓速度不得超過500V/s如果達到水平無擊穿,電壓應保持在該水平60秒。

         

         

        操作臺要求

        1.試驗電流、電壓(測量線圈和電壓互感器值分別顯示)、時間的實時動態(tài)顯示、擊穿瞬間電流、電壓、時間的保持顯示;

        2.合閘、零位、上限、升壓、降壓、恒壓、急停等狀態(tài)監(jiān)控顯示;

        3.操作界面有啟動鈕、停止鈕、急停鈕、高壓指示燈;

        4.有“擊穿”,“耐壓”,“梯度耐壓”選擇開關;

        5.具有“試驗電壓”、“過流閥值”、“升壓速度”、“恒定耐壓時間”、“逐級初始電壓”、“逐級梯度電壓”、“逐級耐壓時間”設置功能;

        6.試驗電壓、電流曲線實時顯示。


         

         

        Test method: dc/ac: breakdown test, compression test, step test
        Display mode: curve/data display, data printing.
        Test space: insulating oil/air
        Pressure rise rate: 0.1 KV/S - 3 KV/S
        High precision: 2% or less

         

         

        Performance characteristics:
        1, mainly by the booster system, measuring system, A/D converter, discharge system, electrode, fuel tanks, electrode positioning, computer data processing system, software, etc;
        2 - A/D converter, computer measurement control system - - - - regulating device step-up transformer - sample;
        3, high voltage transformer is mainly produce samples required dc voltage;
        4, voltage regulator is used to adjust the step-up transformer voltage of the input to generate the input voltage to high voltage;
        5, voltage measurement mainly from high voltage transformer end measurement, high voltage transformer is linear measurement end and high end;
        6 finish after discharge, discharge system in the test, lest produce discharge of bodily harm; (when the experiment ended, the machine parts are still there may be residual high voltage, the residual voltage is enough to cause fatal damage to people, equipped with the rod, solve the potential safety hazard of intact).

         

         

        Composition:
        1, booster parts: consists of a voltage regulator and the high voltage transformer 0 ~ 50 kv booster section.
        2, moving parts: uniform regulation voltage regulator by stepper motor to high voltage transformer voltage change.
        3, test parts: measurement circuit composed of integrated circuit. Through the analog signal and the detection line switch signal to the computer.
        4, computer software, by testing equipment acquisition through inligent circuit of measurement and control signals to the computer. Computer control equipment operation according to the collected information and process the test results.
        5, test electrode: according to the national standard (1408.1-2006) with the equipment to provide three electrodes, specifications are: Ф two 25 mm x 25 mm; Ф a 75 mm x 25 mm. Except (build)

         

         

        Performance characteristics:
        1, mainly by the booster system, measuring system, A/D converter, discharge system, electrode, fuel tanks, electrode positioning, computer data processing system, software, etc;
        2 - A/D converter, computer measurement control system - - - - regulating device step-up transformer - sample;
        3, high voltage transformer is mainly produce samples required dc voltage;
        4, voltage regulator is used to adjust the step-up transformer voltage of the input to generate the input voltage to high voltage;
        5, voltage measurement mainly from high voltage transformer end measurement, high voltage transformer is linear measurement end and high end;
        6 finish after discharge, discharge system in the test, lest produce discharge of bodily harm; (when the experiment ended, the machine parts are still there may be residual high voltage, the residual voltage is enough to cause fatal damage to people, equipped with the rod, solve the potential safety hazard of intact).

         

         

         

        The whole machine:
        1, booster parts: consists of a voltage regulator and the high voltage transformer 0 ~ 50 kv booster section.
        2, moving parts: uniform regulation voltage regulator by stepper motor to high voltage transformer voltage change.
        3, test parts: measurement circuit composed of integrated circuit. Through the analog signal and the detection line switch signal to the computer.
        4, computer software, by testing equipment acquisition through inligent circuit of measurement and control signals to the computer. Computer control equipment operation according to the collected information and process the test results.
        5, test electrode: according to the national standard (1408.1-2006) with the equipment to provide three electrodes, specifications are: Ф two 25 mm x 25 mm; Ф a 75 mm x 25 mm.

         

         

         


        The input voltage: ac 220 V

        Output voltage: communication 0-100 KV; / dc 0-100 KV


        Electric capacity: 10 kva

        High pressure sizing: 0-100 kv

        Pressure rise rate: 0.01 to 5.0 kv (note: meet the standard requirements and can be set according to user requirements different pressure rise rate)


        06, test method: ac/dc test: 1, 2, gradient booster 3 uniform booster, withstand voltage test


        Test medium: air, oil test installation high sensitivity of over current protection device to ensure the sample breakdown within 0.05 S when cut off power supply. The instrument is equipped with advanced fault alarm system Avoid user operation fault instrument. Alarm (the upper machine and lower machine alarm)

         

         

         

        The software functions:
        01, software platform: WINDOWS operating platform, intuitive interface, easy operation
        02, curve shows that: in the process of experiment can dynamically display test curve
        03, data export: can the test results into EXCEL spreadsheet
        04, experimental report: report the name can be set, and the experiment report printing
        05, test mode, can according to demand for flexible choice of dc test and ac test
        06, test method, can according to need to choose the breakdown voltage, compression test, gradient test
        07, parameter setting, can according to different test method and test method for flexible set required different parameter values
        08, sample setting: samples of different standard flexible parameters can be set
        09, personnel management: set the user name and password, different operator login to test different each other
        10, standard options: contain different standards, according to the demand to choose
        11, continuous operation, continuous operation test, can choose motor directly in the software reset, for a second test

         


        Drew dielectric tester of a test of the samples received as an electrode conductor, and the other test lead received as another electrode metal test bar, rose to 28.1 from scratch from voltage should be specified test voltage. Booster speed should not exceed 500 v/s if level and no breakdown, voltage should be kept in the level of 60 seconds.

         

         

        Work station for

        1. The test current, voltage, voltage transformer coil and value respectively display), time of real-time dynamic display, breakdown of instantaneous current, voltage, time keep display;

        2. Switching, zero, ceiling, step-up, step-down, constant pressure and stop condition monitoring display;

        3. The interface has a button, emergency stop button and stop button and high pressure indicator light;

        4. There are "breakdown", "pressure", "gradient pressure" selector switch;

        5. The test voltage, over current threshold ", "booster" speed, "constant pressure time", "initial voltage step by step", "step by step gradient voltage", "graduated compression time setting function;

        6. The test voltage, current curve real-time display.

         

        留言框

        • 產(chǎn)品:

        • 您的單位:

        • 您的姓名:

        • 聯(lián)系電話:

        • 常用郵箱:

        • 省份:

        • 詳細地址:

        • 補充說明:

        • 驗證碼:

          請輸入計算結果(填寫阿拉伯數(shù)字),如:三加四=7
        聯(lián)系人:陳丹
        手機:
        18911395947
        點擊這里給我發(fā)消息
         
        主站蜘蛛池模板: 欧美一级高清片欧美国产欧美| 中文字幕有码在线观看| 国产精品R级最新在线观看| 免费无码日产av| 深夜福利免费在线观看| 韩国论理电影| 国内少妇偷人精品视频| 中文无码乱人伦中文视频在线| 精品一区二区av| 欧美成人精品三级在线观看 | 夜夜嗨av一区二区三区四区| 国产精品流白浆在线观看| 人妻久久| 国产成人午夜福利在线播放| 无码入口| 丝袜足控一区二区三区| 狠狠热在线视频免费| 88XV日韩| 亚洲制服中文字幕一区二区| 在线观看亚洲人成网站| 久久精品国产中文字幕| av在线一区二区三区| 男人的天堂av网站一区二区| 免费国产成人高清视频网站| 亚洲AV无码乱码在线观看裸奔 | 国产欧美一区二区精品仙草咪 | 天天操夜夜操| 麻豆aⅴ精品无码一区二区| 国产伊人网视频在线观看| 性xxxxbbbb| v一区无码内射国产| 国内精品久久久久影院日本| 久久热这里只有精品99| 色欧美片视频在线观看| 国产精品美女挤奶视频| 国产91麻豆视频| 囯产精品一品二区三区| 精品人妻大屁股白浆无码| 18禁高潮出水呻吟娇喘蜜芽| 九九在线中文字幕无码| 国产一性一交一伦一a片|